Architectural flood lights washing a limestone commercial building facade at night

A building may look beautiful in daylight, but it can take on a completely different appearance once the sun goes down. Inappropriately placed lights can cause shadows to stretch across the facade in unattractive ways, create glare, and make building materials look different than they do in daylight. Architectural flood lights are a great way to draw attention to specific objects, illuminate a given structure, and direct light where it is needed most.

When choosing architectural floodlights, contractors and specifiers must consider various factors beyond wattage and cost. Apart from the basics, one must pay close attention to the throw or beam spread, lumens, color temperature, weather resistance, and ease of installation. This article covers everything a specifier, designer, or contractor needs to know about outdoor architectural lighting solutions for commercial lighting projects.

What Are Architectural Flood Lights?


Modern commercial office building illuminated with architectural flood lighting at dusk

Flood lights are used in architectural applications to illuminate building features such as walls, facades, entrances, and other objects that need to be seen clearly in the dark. Usually, they have a wide beam of light spread out over a particular area, as opposed to narrow-beam spotlights. Apart from the basic functionality, choosing architectural flood lights might help to highlight the details of a structure’s composition, provide an even presentation of the objects on the outside of a building, and make it recognizable at night.

It is possible to install architectural flood lighting on office buildings, hotels, retail stores, government offices, courtyards, and other structures. One should pick a fixture based on the surface it will illuminate and the desired effect. Another type of architectural lighting is wall washing, which involves using specialized fixtures to create an even stripe of light on a surface, and grazing, where the light falls onto the plane at a steep angle, also bringing out detail. It is important to decide on the effect for each structure or element and then choose the mounting position and type of lights accordingly.

Evaluate Light Output and Photometric Performance


Even though having a high lumen value is nice, if the fixture’s beam hits the wrong surface, the value may be wasted. To choose the architectural flood lights, one should know more about the target’s receiving light and the area lighting uniformity.

Understand Lumens, Lux, and Foot-Candles

The lumen measurement represents the total amount of light emitted from the fixture. On the other hand, lux and foot-candles are measurements of the light falling on the surface. The foot-candle is a unit of measurement equal to 10.764 lux.

A fixture with a high lumen may underperform by creating dark and bright spots on the surface if not mounted correctly or have an inappropriate beam spread. Several factors influence the final foot-candle measurement, such as hanging height, fixture proximity, surface receptivity, and others.

Review Photometric Data and Beam Angles

Ask manufacturers for photometric data and IES files. These files describe light distribution and help lighting professionals calculate expected illumination before installation. The Illuminating Engineering Society (IES) provides technical resources at ies.org.

Check these factors when comparing fixtures:

  • Beam angle: Narrow beams concentrate light, while wider beams cover larger areas.
  • Mounting distance: The distance between the fixture and target affects coverage and light intensity.
  • Fixture spacing: Poor spacing can create dark gaps or overlapping bright spots.
  • Aiming: Incorrect angles can send light away from the intended surface.

Use photometric calculations to check illumination and uniformity before approving a layout. Don’t rely on advertised lumens alone.

Choose the Right Color Temperature and Color Rendering


Side-by-side comparison of warm white and cool white flood lighting on a stone facade

Color temperature changes how a building looks at night. Correlated color temperature (CCT), measured in kelvins (K), describes the appearance of white light. Warm white light around 2700K to 3000K often complements brick, wood, and warm-toned stone. A neutral appearance around 3500K may suit mixed materials, while 4000K can work well with cooler finishes and contemporary designs.

These ranges are starting points, not strict rules. Test the proposed lighting against the actual building materials and consider nearby pathway, interior, and exterior lighting. Inconsistent color temperatures between adjacent fixtures can make a façade look uneven, even when the light levels match.

Check Color Rendering Index (CRI)

The Color Rendering Index (CRI) measures how accurately a light source renders colors compared with a reference source. A higher CRI can help preserve the appearance of distinctive finishes, paint colors, and architectural details. However, CRI alone doesn’t describe every aspect of color quality.

When specifying LED architectural flood lights, confirm the CCT, CRI, and color consistency in the manufacturer’s documentation. For projects with several lighting zones, matching these characteristics helps maintain a consistent appearance. You can find background information on lighting terminology at ENERGY STAR.

Check Fixture Construction, IP Ratings, and Durability


Outdoor fixtures should be able to withstand inclement weather, including rain, dust, solar radiation, and temperature extremes. Fixtures on coastal jobs may also be required to resist salt laden air which can shorten the life of many components. A fixture that is rated for use in a sheltered entrance may be unsuitable for an open building face.

Understand IP Ratings

An Ingress Protection (IP) rating classifies a fixture’s degree of protection from ingress of solid matter or water. The higher the second number, the greater the degree of protection against water. The higher the first number the greater the protection from solid matter.

Always choose a fixture based on its actual installation location. Take into account such factors as rain and water spray, dust, and ease of cleaning. Note that not all outdoor rated fixtures are cut out for coastal or high humidity environments, and that specification should be based on more than a manufacturer’s claims. Check the documentation for the specific product you are considering.

Review Materials and Thermal Management

Make sure that a fixture has a durable housing material, appropriate finishes, and corrosion resistant hardware. Fixtures on jobs near the coast in Southern California or other areas where salt air is common, should also be resistant to salt damage. The buildup of heat can also impact a fixture’s performance.

Check the maximum operating temperature, the driver spec, lifetime claims, and warranty information. Remember that many LED drivers and other components’ warranties are not tied to the claimed lifetime of the fixture, but rather its operating temperature.

For product safety information, consult UL Solutions and verify the certifications that apply to the specific fixture.

Plan Mounting, Aiming, and Installation


The position of the lights plays an essential role in achieving the desired effect. Thus, wall-mounted fixtures can be used to highlight the details of the building’s facade. At the same time, ground- or pole-mounted lights may be used on a more significant scale to show off the architectural structure from a distance. It is necessary to ensure the correct height, setback, windows, and balconies, pedestrian walkways, and the overall configuration of a building to plan the location of each fixture.

Choose Suitable Mounting and Accessories

It is essential to consult the fixture specification regarding the aiming capability and possible accessories. Aiming capabilities should be considered by the architect when choosing the location and rotation of the light. Various shields, visors, and louvers can be used to control glare; thus, the selected accessory should match the characteristics of the fixture.

Coordinate Electrical Requirements

The architect should specify the supply voltage, driver requirements, dimming capabilities, routing of wiring, and locations of junction boxes, mounting hardware, and future servicing accessibility. This information should also be included in the lighting plan and fixture schedule for contractors.

A fixture, which seems to fulfill all the technical requirements, still can fail to deliver the expected result due to an improper position or direction. Therefore, it is vital to examine installation notes and perform calculations of light distribution to obtain the final drawing approval.

Control Glare, Light Spill, and Skyglow


Bright exterior lighting can cause discomfort when pedestrians, drivers, building occupants, or neighbors look directly at an exposed light source. Poor aiming can also send light through nearby windows or beyond the property boundary. Address these problems during the design stage rather than waiting until installation.

Reduce Glare and Unwanted Light

Choose optics that suit the target surface, position fixtures carefully, and use compatible shielding when necessary. Avoid excessive output if a lower level can achieve the intended result.

Uncontrolled upward light can contribute to skyglow, while unwanted illumination can disturb nearby properties and wildlife. Precise aiming, suitable output levels, and scheduled controls help keep light within the intended area and operating hours.

Understand BUG Ratings

The IES Backlight, Uplight, and Glare (BUG) rating system helps designers assess unwanted light distribution and compare suitable luminaires. These ratings provide useful information, but they don’t replace photometric calculations or local lighting requirements.

Visit DarkSky International for responsible outdoor lighting guidance and review the IES and IDA Model Lighting Ordinance for additional context.

Key Takeaway: Direct light where it serves a purpose, use only the intensity the project requires, and avoid unnecessary illumination.

Compare Energy Use, Controls, and Operating Costs


Luminaire efficacy, measured in lumens per watt (lm/W), indicates how much light a fixture produces for each watt of electrical input. This is useful when comparing commercial outdoor lighting, but the highest figure doesn’t automatically identify the best product. Beam distribution, color quality, glare control, and the project’s actual lighting needs matter too.

Use Controls to Reduce Unnecessary Lighting

Depending on the application, consider dimming, photocells, astronomical time switches, occupancy sensors, or centralized controls. Photocells respond to ambient light, while astronomical time switches can coordinate operation with sunset and sunrise. Dimming lets you lower output when full illumination isn’t needed.

Check compatibility between the fixture, driver, and control system before specifying the equipment. You should also confirm any applicable requirements for automatic shutoff and lighting controls.

Calculate Total Cost of Ownership

The purchase price is only one part of the cost. Compare fixtures based on:

  • Initial fixture and installation costs.
  • Electricity use over expected operating hours.
  • Routine cleaning and maintenance.
  • Potential driver or component replacement.
  • Expected service life and warranty coverage.

A less expensive fixture may cost more to operate or maintain over time. Use realistic operating hours, energy rates, and maintenance assumptions when comparing options. For California projects, consult the California Energy Commission’s 2025 Building Energy Efficiency Standards for applicable energy and control requirements.

Verify Building Codes and Safety Standards


Architects reviewing building renderings, lighting plans, and photometric layouts for flood light specification

Architectural flood lights must meet the requirements that apply to the building, installation, and jurisdiction. Product safety certification, electrical installation rules, energy codes, and local lighting ordinances address different aspects of compliance.

Check Product Certifications

Verify the fixture’s applicable safety listing, installation classification, and suitability for wet locations. UL 1598 is a relevant luminaire safety standard, but you should confirm the specific product’s certification and applicable requirements rather than assume every fixture complies.

Review California Energy Requirements

California Title 24, Part 6, includes energy requirements for applicable nonresidential outdoor lighting systems. The 2025 California Energy Code generally applies to relevant building permit applications submitted on or after January 1, 2026, subject to its scope and provisions.

Check applicable lighting power limits, control requirements, documentation, and exceptions. Local ordinances may impose additional restrictions on exterior lighting, especially near residential properties or environmentally sensitive areas.

Prepare a fixture schedule, product cut sheets, photometric reports, mounting details, and control sequences. Confirm the applicable code edition and local amendments with the responsible design professional and authority having jurisdiction.

Use an Architectural Flood Light Specification Checklist


A clear specification helps you compare manufacturers, review product submittals, and catch missing details before construction begins. Use the following table when preparing a fixture schedule or checking a proposed product.

Specification Item What to Verify
Light output Delivered lumens, required illuminance, and uniformity
Beam distribution Beam angle, IES file, aiming, and fixture spacing
Color quality CCT, CRI, and color consistency
Construction IP rating, housing material, corrosion resistance, and temperature limits
Installation Mounting method, electrical requirements, and maintenance access
Controls Dimming compatibility, scheduling, and photocell requirements
Compliance Applicable certifications, energy code requirements, and local ordinances
Long-term costs Warranty, expected service life, maintenance, and electricity use

Review Manufacturer Submittals

Compare the proposed fixture with your original specifications. Confirm that its photometric performance, dimensions, mounting accessories, and control compatibility meet the design requirements. If a contractor proposes a substitute, review its photometric data instead of accepting it based on wattage or appearance alone.

Hevi Lite offers architectural, commercial, and outdoor lighting fixtures designed, developed, and manufactured in California. Review the documentation for each product to confirm its suitability for your project. Don’t assume that every fixture offers the same lumen output, IP rating, or control options.

Conclusion: Specify Architectural Flood Lights With Confidence


Good architectural flood lighting starts with the right specifications. Check photometric performance, color quality, durability, mounting, glare control, energy use, and code compliance before approving a fixture. These details help you achieve the intended appearance while avoiding unwanted light and unnecessary operating costs.

For information about architectural, commercial, and outdoor lighting options, contact Hevi Lite in San Fernando Valley, California, at (818) 341-8091.

Frequently Asked Questions


1. What is the difference between architectural flood lights and regular flood lights?


Architectural flood lights emphasize controlled distribution, color quality, and building appearance. General-purpose flood lights often focus on broad visibility or security.

Required lumens depend on the target area, mounting distance, beam distribution, surface reflectance, and desired illuminance. Use photometric calculations to determine suitable output.

Warm white often complements traditional materials, while neutral or cooler white may suit contemporary finishes. Test the color against the actual materials and nearby lighting.

Choose an IP rating based on exposure to dust, rain, and water spray. Confirm that the fixture suits its intended installation conditions.

Choose suitable optics, aim fixtures carefully, use compatible shielding, avoid excessive output, and apply controls that limit unnecessary nighttime illumination.